Load Station 시리즈는 500V이하에서 빠른 스피드를 요구하는 대부분의 연구개발에 대응이 가능하도록 설계된 제품입니다.
Model | Max rating | Slew rate | ||
Voltage | Current | Power | ||
LN-300A-G7 | 120V | 60A | 300W | 20A / us |
LN-300C-G7 | 500V | 12A | 300W | 1A / us |
Lower voltage operation
There is no operating limitation by Loading Voltage since this series sink load current as far as voltage difference exists.
Parallel operation (Booster function)
Up to 5 sets of Load Station series can be paralleled to expand loading power. It can configure max. 10kW load (LN-1000A X 10 sets). Different power modes can also be paralleled as far as they are same voltage rating.
Ripple & Noise measurement
With optional Ripple & Noise measurement function, it can configure as a power supply tester for power supply testing application.
Sequence function
Max. 1024 steps of sequence operation is possible from PC for various loading. Complicated loading condition can be simulated.
The Load Station series is equipped with various features suitable for evaluation and inspection applications.
External control mode (0 – 10V) can control load current externally, Current monitor for load current monitoring (not isolated), GPIB as well as USB interface.
Low inductance loading cable : Low-L Cable (Option)
The cables designed for low inductance. With this cable, voltage drop may be minimized. 50cm, 100cm and 200cm possible.
Electronic Load Section | LN-300A-G7 | LN-300C-G7 | ||
Max rating | ||||
Current | 60A | 12A | ||
Voltage | 120V | 500V | ||
Internal min resistance(*9) | 17m ohm | 250m ohm | ||
Min operating voltage(*8, 9) | 1V(60A) / 0.5V(30A) / 0.2V(12A) | 3V(12A) / 1.5V(6A) / 0.7V(2.4A) | ||
Rate power | 300W | |||
CC mode | ||||
Current range (Setting range) | H | 0 – 60A | 0 – 12A | |
M | 0 – 6A | 0 – 1.2A | ||
L | 0 – 0.6A | 0 – 0.12A | ||
Nominal resolution(*1) | H | 5mA | 1mA | |
M | 0.5mA | 0.1mA | ||
L | 0.1mA | 0.02mA | ||
Accuracy(*4) | H | +/- 0.2% of stg. +/- 25mA+Vin/Rin | +/- 0.2% of stg. +/- 10mA+Vin/Rin | |
M | +/- 0.2% of stg. +/- 12mA+Vin/Rin | +/- 0.2% of stg. +/- 3mA+Vin/Rin | ||
L | +/- 0.2% of stg. +/- 6mA+Vin/Rin | +/- 0.2% of stg. +/- 2mA+Vin/Rin | ||
CR mode | ||||
Voltage range | 20V | 85V | ||
Resistor range (Setting range) | Current range:H | 0.025 – 200 ohm | 0.3 – 2.5k ohm | |
Current range:M | 0.25 – 2K ohm | 3 – 25k ohm | ||
Nominal resolution(*1) | Current range:H | 4ms | 333us | |
Current range:M | 400us | 33us | ||
Voltage range | 120V | 500V | ||
Resistor range (Setting range) | Current range:H | 0.075 – 600 ohm | 0.9 – 7k ohm | |
Current range:M | 0.75 – 6k ohm | 9 – 70k ohm | ||
Nominal resolution(*1) | Current range:H | 1.33ms | 111us | |
Current range:M | 133us | 11us | ||
Accuracy(*2, 4, 6) | +/- 0.5% of Conv. Curr. +/- 0.2% of f.s. +Vin/Rin | |||
CV mode | ||||
Voltage range (Setting range) | H | 0 – 120V | 0 – 500V | |
L | 0 – 20V | 0 – 85V | ||
Nominal resolution(*1) | H | 10mV | 50mV | |
L | 2mV | 10mV | ||
Accuracy | +/- 0.2% of stg. +/- 0.2% of f.s. | |||
Response time | Fast/Slow (300us/10ms Typ) | |||
CP mode | ||||
Power range | Current range:H | 0 – 300W | ||
Current range:M | 0 – 40W | |||
Nominal resolution(*1) | Current range:H | 50mW | ||
Current range:M | 5mW | |||
Accuracy(*4) | +/- 2.5% of stg. +/- 1% of f.s. +/- (VinXVin)/Rin | |||
External control mode | ||||
Current range (Setting range) | H | 0 – 60A | 0 – 12A | |
M | 0 – 6A | 0 – 1.2A | ||
Nominal resolution(*1) | H | 10mA | 2mA | |
M | 1mA | 0.2mA | ||
Accuracy(*4, 5) | +/- 0.2% of stg. +/- 0.5% of f.s. +Vin/Rin | |||
Control voltage | 0 – 10V | |||
Dynamic load mode | ||||
Control method | Switching | |||
Loading mode | CC/CR/CV/CP mode | |||
Setting period | -20ms / -200ms / -2s / -20s / -60s | |||
Period resolution | 1us / 10us / 100us / 1ms / 10ms | |||
Operating mode | Continuous, Single | |||
Slew rate (Current range) | H | 0.2 – 20A/us | 0.01 – 1A/us | |
M | 0.02 – 2A/us | 0.001 – 0.1A/us | ||
L | 0.002 – 0.2A/us | 0.0001 – 0.01A/us | ||
Min load response time(*3) | 500ns | |||
Sequence mode | ||||
Loading mode | CC / CR / CV / CP mode | |||
Max steps | 1024 | |||
Step duration | 1ms – 10min | |||
Duration resolution | 1ms(1ms – 100ms) / 100ms(100ms – 10min) | |||
Short mode | ||||
Short current (MAX) | 60A | 12A | ||
Current limit setting | ||||
Current range (Setting range) | H | 0.3 – 60A | 0.06 – 12A | |
M | 0.03 – 6A | 0.006m – 1.2A | ||
Parallel operation | ||||
Master-Slave operation. One master unit can control up to 9 units of slaves of same voltage rating. For example: If the master unit is LN-300A-G7 then LN-300A-G7, LN-1000A-G7 may be connected as slave unit. |