Maximum total voltage at current source leads
275V dc(larger battery systems can be sectioned to accommodate this specification)
Transmitter
Supply voltage
100 to 130V, 50/60Hz, 200VA max
2100 to 250V, 50/60Hz, 200VA max
Source output current
10 a nominal, 50/60Hz operation
Maximum battery string test voltage
275V dc at source lead terminals (section the battery if>275Vdc)
Display
Digital LCD meterm 0 to 15A
BITE2P Printer
Built-in thermal, with 4.25 in. (110mm)printing with
Charger
Supply voltage
100 to 130V, 50/60Hz, 14VA
210 to 250V, 50/60Hz, 14VA
Output
6.50V dc @ 1.10 A dc charging(max)
9.60 V dc open circuit
Receiver
Accuracy
ac impedance 5%+1 LSD
dc voltage ±(0.5% one sigma)
Precision
Better than 0.5% one sigma
Voltage range and resolution
1 to 2.500 V dc, 1 mV resolution
25 to 2.500 V dc, 10 mV resolution
Impedance range and resolution
0 to 1.000 mΩ, 1μΩ resolution
1 to 10.00 mΩ, 1μΩ resolution
10 to 100.0 mΩ, 0.1mΩ resolution