Current output range(a.c) |
20A to 2000A(0 to 3V)50Hz60Hz (programmable in 10 A steps) 40A to 1000A(0 to 6V)50Hz60Hz (programmable in 10 A steps) |
Accuracy |
Output ±2.5% of programmed value note : Motor Variac Driven – subject to mains variation |
Auxiliary voltage output(a.c.) |
0 to 250V, 2A, 50Hz60Hz 0 to 125V, 2A, 50Hz60Hz |
Display |
Dot matrix L.C.D |
Measurement ranges current |
0-2000A, resolution 1A |
50Hz60Hz voltage/current |
0-250V, resolution 1V 0-2A, resolution 0.01A |
Accuracy |
±3% of reading, ±2 digits |
Duty cycle |
21/2 minutes on circuit and 15 minutes off circuit al full Range current and voltage. Duty cycle increases until continuous use is possible at 40% of full range |
Temperature range operation |
0oC to 40 oC(32to 104 oF) |
Temperature range storage |
-20oC to +60 oC(-4to 140 oF) |
Humidity range operation |
90% RH at 40 oC(104 oF) |
Humidity range storage |
90% RH at 40 oC(104 oF) |
Supply voltage |
220V/240V + 6%-10%, 50Hz60Hz7kVA |
Timer stop inputs |
Unenergised or 100V to 264V a.c./d.c. energised contacts |
Safety |
The test set will, in general, meet the requirements of the IE061010-1 |
Equipment protection |
30 A rating |
Auxiliary output fuse |
2 A ceramic HBC 20mm X 5mm IEC127/1 |
Controller supply fuse |
1A ceramic HBC 20mm X 5mm IEC127/1 |
Dimenions |
320mm x 305mm x 510mm(121/2in x 12in x 20 in approx) Excluding handle and wheels |
Controller |
20mm x 127x 55m(8in x 5in x 21/8 in approx) |
Weight |
61kg(134lb approx) |